Vector S™ Device Firmware
Σελίδα 1 από 1
Vector S™ Device Firmware
[Πρέπει να είστε εγγεγραμμένοι και συνδεδεμένοι για να δείτε αυτή την εικόνα.]
[Πρέπει να είστε εγγεγραμμένοι και συνδεδεμένοι για να δείτε αυτόν το σύνδεσμο.]
as of June 22, 2016
Change History
Changes made from version 3.90 to 4.00:
Properly enable the status LED to prevent the unit from appearing non-functional when an incomplete mechanical connection between the pod and spindle occurs.
Changes made from version 3.81 to 3.90:
Correct accelerometer start-up error that was preventing meaningful data from being captured and reported
Fixed a condition where Vector could cause a display to divide by zero when receiving torque data
Install angle can be set in a pedal to pedal disconnected state.
Improved battery monitoring to make it less susceptible to sampling noise
Improved handling of parameter conflict between multiple displays
Prevent users from setting scale factor outside of the 0.75 to 1.25 range
Changes made from version 3.50 to 3.81:
Corrected two radio issues that were causing persistent loss of data reception either from the left side or from the entire system.
Improved pedal to pedal sync time.
Reduced opportunities for spontaneous un-pairing of pedals.
Corrected a math error that was causing periodic balance spikes.
Transmit time-averaged torque while coasting.
Changes made from version 2.71 to 3.50:
Added rider position determination (Seated/Standing) cycling dynamic when connected to a compatible Garmin display [dual sensing Vector 1 and 2 systems only].
Made static offset calibration time constant; it will always take 5 seconds if successful.
Enabled pairing and unpairing of Vector S and 2S pedals from a compatible Garmin display.
Improved speed of connecting to pedals for firmware upgrade from a compatible Garmin display.
Improved initiation of cycling dynamics from a compatible Garmin display [dual sensing Vector 1 and 2 systems only].
Allow TE/PS to be enabled or disabled on compatible Garmin display devices [dual sensing Vector 1 and 2 systems only].
Fixed issue where the install angles were not properly being reset when unplugging the spindle or when commanded by a compatible Garmin display.
Various fixes to address issues related to calibration errors, left pedal drop outs and poor TE/PS data.
Changes made from version 2.70 to 2.71:
Fixed messaging issue that would prevent a partially failed upgrade from being successfully retried.
Changes made from version 2.60 to 2.70:
Add calculation and output of Cycling Dyanmics, Power Phase.
Add calculation and output of Cycling Dynamics, Peak Power Phase.
Add calculation and output of Cycling Dynamics, Platform Centre Offset (PCO).
[Πρέπει να είστε εγγεγραμμένοι και συνδεδεμένοι για να δείτε αυτόν το σύνδεσμο.]
as of June 22, 2016
Change History
Changes made from version 3.90 to 4.00:
Properly enable the status LED to prevent the unit from appearing non-functional when an incomplete mechanical connection between the pod and spindle occurs.
Changes made from version 3.81 to 3.90:
Correct accelerometer start-up error that was preventing meaningful data from being captured and reported
Fixed a condition where Vector could cause a display to divide by zero when receiving torque data
Install angle can be set in a pedal to pedal disconnected state.
Improved battery monitoring to make it less susceptible to sampling noise
Improved handling of parameter conflict between multiple displays
Prevent users from setting scale factor outside of the 0.75 to 1.25 range
Changes made from version 3.50 to 3.81:
Corrected two radio issues that were causing persistent loss of data reception either from the left side or from the entire system.
Improved pedal to pedal sync time.
Reduced opportunities for spontaneous un-pairing of pedals.
Corrected a math error that was causing periodic balance spikes.
Transmit time-averaged torque while coasting.
Changes made from version 2.71 to 3.50:
Added rider position determination (Seated/Standing) cycling dynamic when connected to a compatible Garmin display [dual sensing Vector 1 and 2 systems only].
Made static offset calibration time constant; it will always take 5 seconds if successful.
Enabled pairing and unpairing of Vector S and 2S pedals from a compatible Garmin display.
Improved speed of connecting to pedals for firmware upgrade from a compatible Garmin display.
Improved initiation of cycling dynamics from a compatible Garmin display [dual sensing Vector 1 and 2 systems only].
Allow TE/PS to be enabled or disabled on compatible Garmin display devices [dual sensing Vector 1 and 2 systems only].
Fixed issue where the install angles were not properly being reset when unplugging the spindle or when commanded by a compatible Garmin display.
Various fixes to address issues related to calibration errors, left pedal drop outs and poor TE/PS data.
Changes made from version 2.70 to 2.71:
Fixed messaging issue that would prevent a partially failed upgrade from being successfully retried.
Changes made from version 2.60 to 2.70:
Add calculation and output of Cycling Dyanmics, Power Phase.
Add calculation and output of Cycling Dynamics, Peak Power Phase.
Add calculation and output of Cycling Dynamics, Platform Centre Offset (PCO).
Santosan- Administrator
- Ηλικία : 54
Τόπος : Athens - West Side
Ημερομηνία εγγραφής : 06/10/2012
Αριθμός μηνυμάτων : 10879
Παρόμοια θέματα
» Vector™ Device Firmware
» Vector™ 2 Device Firmware
» Vector 2S™ Device Firmware
» HRM-Run Device Firmware
» HRM-Run Device Firmware
» Vector™ 2 Device Firmware
» Vector 2S™ Device Firmware
» HRM-Run Device Firmware
» HRM-Run Device Firmware
Σελίδα 1 από 1
Δικαιώματα σας στην κατηγορία αυτή
Δεν μπορείτε να απαντήσετε στα Θέματα αυτής της Δ.Συζήτησης